How do I choose a hydraulic gear pump?
Judgment of rotation direction of one-way gear pump:
1. Since the one-way gear oil pump has a unique rotation direction, using the wrong rotation direction will damage the internal parts of the product, so the rotation direction of the product must be correctly judged before use.
method 1:
Judge according to the hydraulic pilot pump nameplate.
① Face the nameplate of the hydraulic gear pump towards yourself and observe the arrow mark on the nameplate.
②When the arrow on the nameplate points to the right, the rotation direction of the gear pump (motor) is left-hand (counterclockwise code: L).
③When the arrow on the nameplate points to the left, the rotation direction of the gear pump (motor) is right-hand (clockwise code: R).
Method 2:
Judgment based on matching motor (engine)
①Facing the motor (engine) power output shaft, observe the rotation direction of the power output shaft
② When the rotation direction of the power output shaft is clockwise, the matching gear pump rotation direction is left-hand (counterclockwise code: L).
③When the rotation direction of the power output shaft is counterclockwise, the matching gear pump rotation direction is right-hand (clockwise code: R)
Method 3:
judge based on the actual object.
Note: Under normal circumstances:
One-way gear oil inlet > oil outlet
Oil inlet < oil outlet of one-way gear motor.
① Correctly determine the oil outlet of the gear oil pump (motor), place the oil outlet facing you, and observe the shaft extension of the gear oil pump (motor)
②When the shaft extension is located on the left side of the oil outlet (as shown in Figure 1), the rotation direction of the gear oil pump (motor) is left-handed (counterclockwise code: L).
③When the shaft extension is located on the right side of the oil outlet (as shown in Figure 2), the rotation direction of the gear oil pump (motor) is right-hand (clockwise code: R).
2. Common installation dimensions
1. The mounting flange and shaft extension dimensions are in accordance with the requirements of GB/T2353-2005
2. The type and size of the threaded connection port shall comply with the requirements of GB/T2878-1993
3.SAB installation standards
mounting flange | flange dimensions(mm) | Flange height(mm) | Front end cover mounting hole(mm) | Common oil port and flange size(mm) | |
Two-hole mounting | Four-hole mounting | ||||
SAB"A" flange | ⊘82.5 | 6.3 | 2-⊘11, center distance 106 |
20/47.6X22.2/M10 25/52.4X26.2/M10 35/69.9X35.7/M12 50/ 77.8X42.9/M12 |
|
SAB"B" flange | ⊘101.6 | 9.4 | 2-⊘14, center distance 146 | 4-⊘14/▢89.8 | |
SAB"C" flange | ⊘127 | 12.7 | 2-⊘18, center distance 180 | 4-⊘14/▢114.5 |